30
GB
31
GB
Maintenance operations to be carried out approximately once a year
• Unplug and unload the appliance.
• Clean the water drain at the bottom of the wine cabinet. Pay attention that nothing is
blocking this drain.
• Regularly vacuum the condenser at the back of the appliance.
• Clean the inside of the compartments with water and a gentle cleaning product.
• Rinse thoroughly.
• Dry it with a soft rag.
• Replace the active charcoal filter in the breather hole at the top of your cabinet.
• Remove the charcoal filter manually. It is available from your usual retailer. It must be
replaced by an original manufacturer’s part.
• Check that the seals are in good condition. It is often necessary to clean the door seal.
Using unsuitable cleaning products can cause premature ageing of the seals. Certain
rules must therefore be followed: whenever you clean the seal, always rinse off any
cleaning product with clear water. All traces of cleaning product must be removed from
the seal. EuroCave Professional only recommends using a mild soapy solution. If this
proves insufficient, it is possible to occasionally use an ethanol-based solution, provided
that the concentration used is less than 10% and that the seal is then rinsed thoroughly
with clear water.
Your EuroCave Professional cabinet is a tried and tested appliance.
Caring for glass elements:
• To clean the glass elements of your cabinet, use a non-abrasive soft cloth which has had a suitable glass cleaning product applied to it.
Minimum duration of guarantee offered by the manufacturer: 2 years parts.
7/ EVERYDAY MAINTENANCE
Regular monitoring of your cabinet and reporting any faults to your retailer will ensure that your appliance provides you
with many years of faithful service.
Possible incidents
Causes
Corrective actions
The
pictogram is displaying
The inner temperature is above
4°C compare to the setting
temperature.
Check that the door is correctly closed.
Check the condition of the door seal.
If you placed a large amount of bottles in your cabinet in the last few hours,
wait a while then check again. If the alarm is still displaying, contact your
EuroCave Professional retailer.
The
pictogram is still displaying
even though I have taken the
corrective actions above
Operating fault
Unplug the cabinet and contact your EuroCave Professional retailer.
The
pictogram is flashing
The level of relative humidity
has been < 50 % for over 72 hrs
• Pour a glass of water into the duct of the tray (see chapter 7, § IV).
• In order to know how often to add water, count the number of days
separating the 1st day you added water and the day when the pictogram
was displayed
After a few hours, the pictogram will disappear.
The appliance cannot lower the level
of humidity to the desired value
• Empty the cabinet, remove the humidity cartridge and clean the tray.
• Remove the tube placed at the back of the tray. The humidity will be
directly discharged out of the appliance.
Call the EuroCave Professional retailer if the problem persists despite
having carried out these different operations.
The
pictogram is displaying
Charcoal filter alarm
Replace the charcoal filter (see chapter 4).
The
pictogram is displaying
Temperature sensor fault alarm
Contact your EuroCave Professional retailer.
If your appliance does not seem to be working correctly, contact your EuroCave Professional retailer.
4000
Height
1
Width
Depth
2
Weight when empty
Recommended temperature range
mm
mm
mm
Glass door (Kg)
Solid door (Kg)
Min T°(°C / °F) - Max T° (°C / °F)
Glass
Solid door
1 temperature
V-4000-L
1825
680
715
92
78
0-30 / 32-86
0-35 / 32-95
Multi-temperatures
S-4000-L
1825
680
715
92
78
12-30 / 54-86
12-30 / 54-86
1
Height including the top hinges and the feet, adjusted to mid-height.
2
Depth including the separator at the back of the cabinet for air ventilation. Handle not included.
According to delegated regulation (EU) 2019/2016 of the European Commission, access energy data about our appliances on the EPREL database by
scanning the QR code visible on your appliance’s energy label.
The use of glass doors can alter your wine cabinet’s performance in some extreme temperature conditions.
8/ OPERATING FAULTS
9/ TECHNICAL FEATURES AND ENERGY DATA