11
EN
8.
TROUBLESHOOTING
GRINDER CONDITION
CAUSE
POSSIBLE REMEDY
When the grinder is switched
ON using button
(5)
, it does
not start.
Switch
(9)
in the "START" posi-
tion at the time of switching
ON.
Turn the switch
(9)
to the
"STOP" position and then to
the "START" position to begin
the grinding process.
The grinder is operating nor-
mally, but the LED of the switch
(9)
blinks slowly.
The grinding chamber has
reached 45°C.
Stop grinding to allow cooling
of the grinding chamber.
The cooling fan remains active
until the temperature returns
below 45°C and, for safety
reasons, remains active for a
further 180 seconds.
The grinder is operating nor-
mally, but the LED of the switch
(9)
blinks quickly.
Temperature probe faulty.
Use the grinder moderately,
because the temperature of
the grinding chamber is not
monitored.
Replace the temperature probe
by a qualified technician.
If the problem persists, contact skilled personnel.