13) Parameter group 600: DC-Brake control / aux. functions
Brake Chopper control (internal brake chopper)
F612
Max. duty-cycle chopper
Range: 0…100 %
Default setting: 100 %
"Catch on the fly" function: To get already spinning motor controlled (V/Hz mode only)
F613
Activation of the function
Selection: 0: Function deactivated
1: Always active
2: Active after POWER_ON
Default setting: 0
F614
Scan process starting from:
Selection: 0: Last memorized frequency
1: Starting from f-max
2: Starting from 0HZ
Default setting: 0
F615
Scan speed
Range: 1…100
Default setting: 20
F620
Brenschopper Disable after STOP
Range: 0,0…3000 sec.
Default setting: 5,0 sec.
F620=0,0:
Brake chopper may activate in STOP mode as well (if DC voltage rises), if
F620>0:
brake chopper function will
deactivate in STOP mode after the time in F620.
Parameter Copy functions
Please refer to copy STICK description
F638
Parameter Copy
Selection: 0: Copy function disabled
1: Enabled, with identical
powersize/voltage range
2: Always enabled
Default seting: 1
F639
KopyCode
3000....3499 READ
ONLY
F638
Parameter selection for copy
function
Selection:
0: All parameter
1: Motor parameter (F8xx) excluded
Default setting: 1
F644
Keypad copy
Range 0: disable
1:Upload parameters
2:Dopwnload parameters
Default setting: 0
Parameter set copy to/from keypad - after setting 1/2, RUN key starts the process
Attenuation function to prevent from torque oscillation (motor vibration at low frequencies)
It works in V/Hz mode only
(F137=0,1,2
), "Catch on the fly" function to deactivate
(F613=0
)
F641
Anti-oscillation-function activation
Range 0: disable
1%....100% activated
Default setting: 10%
EM30 – Rev.03 -EN- SOFT Rev. 1.1x
© 2017-06-KPP-EURADRIVES EUROPE GmbH
50
Summary of Contents for EM30 Series
Page 70: ...NOTES...
Page 71: ...NOTES...