11) Parameter group 400: Analog I/O configuration
Pulse speed reference signal input configuration:
Configuration is done in the same way, as for analogue speed reference signal. DI1 is predetermined as pulse
signal input channel. DI1 selection is done automatically, if pulse reference signal is selected as speed reference
source. Maximum input frequency: 50 kHz.
F440
Min. pulse frequency (kHz)
Range: 0.00…F442
Default setting: 0.00 kHz
F441
Assignation min. frequency
Range: 0.00…F443
Default setting: 1.00
F442
Max. pulse frequency (kHz)
Range: F440…50.00 kHz
Default setting: 10.00 kHz
F443
Assignation min. frequency
Range: Max
(
1.00
,
F441
)
…2.00 Default
setting:
2.00
F445
Filter factor pulse input
Range: 0…100
Default setting: 0
F446
0 Hz dead-band
Range: 0…+/- F442
Default setting: 0.00
Range configuration and dead band selection will be done in the same way, as for analogue input signals
Non-linear characteristic for analogue channels
A non-linear characteristic can be assigned to analogue input channels
AI1
and
AI2
. Programming is done in
sense of the table below
F460
Characteristic
AI1
Selection: 0=linear
1=non-linear
Default setting: 0
F461
Characteristic
AI2
Selection: 0=linear
1=non-linear
Default setting: 0
F462
input level 1 for
AI1
Range: F400 - F464
Default setting: 2.00V
F463
Assignation input level 1 (%)
Range: F401 - F465
Default setting: 1.20
F464
input level 2 for
AI1
Range: F462 - F466
Default setting: 5.00V
F465
Assignation input level 2 (%)
Range: F463 - F467
Default setting: 1.50
F466
input level 3 for
AI1
Range: F464 - F402
Default setting: 8.00V
F467
Assignation input level 3 (%)
Range: F465 - F403
Default setting: 1.80
F468
input level 1 for
AI2
Range: F406 - F470
Default setting: 2.00V
F469
Assignation input level 1 (%)
Range: F407 - F471
Default setting: 1.20
F470
input level 2 for
AI2
Range: F468 - F472
Default setting: 5.00V
F471
Assignation input level 2 (%)
Range: F469 - F473
Default setting: 1.50
F472
input level 3 for
AI2
Range: F470 - F412
Default setting: 8.00V
F473
Assignation input level 3 (%)
Range: F471 - F413
Default setting: 1.80
100
Assignation of intermediate pints, in the same way as for endpoints
(0= -100%, 1=0%, 2=+100%)
F400
A1 A2 A3
F402
EM30 – Rev.03 -EN- SOFT Rev. 1.1x
© 2017-06-KPP-EURADRIVES EUROPE GmbH
- 46 -