2) Product data / Product naming convention
Technical data - inverter series E30
Power supply
Rated voltage
3-phase 380…460V +/- 15% - 1phase 230V +/- 15%
Input frequency
44….67 Hz
EMC filter
Integrated for 2. environment - optional for 1st environment
Output
Output voltage
0……...U-input
Output frequency
0……...650 Hz
Resolution of output frequency
0,01 Hz
Overload capability
150% - 60 sec. / 10 Min
Control mode
PWM control-modes
V/Hz - Mode
SENSORLESS VECTOR (SLV) – Speed / torque control
Permanentmagnet Synchronus Motor PMM control
PWM frequency
0,8.....16 kHz
V/Hz characteristic
Linear, quadratic, and user-programmable curve – independent output
voltage via setpoint
Starting torque
150% rated torque at 0,5 Hz (in SLV mode)
Torque boost
Automatic / manual
Motor data input
Manual input / intelligent AUTOTUNING function
Speed range
1:100 in SLV mode
Speed precision
+/- 0,5% (SLV)
Torque precision
+/- 5% (SLV)
DC-Brake
Freq. threshold, duration and intensity programmable – DC injection
Brake chopper
Integrated chopper transistor (Brake resistors – see product table)
Display
4 line LCD character display
For programming and visualization of different operating parameters
I/O Channels,
control functions
Inverter control - Start/Stop
To configure: terminals / keypad/ serial link
Digital control inputs
6 digital inputs (HIGH/LOW configurable), pulse input
Speed / torque reference signal
Potentiometer/analogue input (terminals), via keypad, pulse input, serial link
Analogue setpoint input
2 Analogue channels 0…10V, 0..(4)20 mA (with programmable offset and
gain – to concatenate mathematically each other)
Analogue outputs
2 analogue output channels, both programmable in gain, different functions
to assign (0…10V, 0..20 mA)
Digitale outputs
1 digital output (different functions to assign)
Relays output
2 switchover contact 5 A 230 V (programmable for different functions)
Interface Serial
link (MODBUS – ASCI/RTU)
Special function - control options
Jog mode, 12V / 50 mA auxiliary power supply on terminals
PI-control / Pump control, Master/Slave control, multipump control
Fixed frequency control, programmable cycling frequency sequence
"Catch on the fly function", AUTORESET/RESTART function
Protections with
fault memory
Electrical protections
Overvoltage, undervoltage
Overcurrent, overload, motor overload short circuit
Phaseloss, moptor phase imbalance
Thermal protections
Ovetemperature, motor I
2
xt, motor PTC/KLIXON protection
Optionals
Operating panel
Remote keypad / programming tool
Brake resistors
High power resistors for heavy duty operation
Filter / chokes
PFC chokes – dv/dt limiting output filter - sinusfilter
Parameter copy stick
USB Stick with parameter dublication function – USB/RS485 converter
PC-Link Software (via MODBUS)
Special tool for programming, control and diagnostic (parameter set memory)
Environmental
conditions
Protection IP66
Operating temperature
-10……+50 °C
Humidity
Max. 90 % not condensing, no corrosion
Elavation
1000 m - 1% derating / 100m above
Vibration
Max. 4 g
Power range
Size
J1 - J2
0,4……7,5
kW
Standards
EMC EN61800-3(2004)
Safety EN61800-5-1
2003
EM30 – Rev.03 - EN- SOFT Rev. 1.1x
© 2017-06-KPP-EURADRIVES EUROPE GmbH
- 12 -