6.1. Block diagram CES-A-UBA-…
24V
TST
TST
input not connected:
Operation without external testing
0V
OUT
ERR
GND
H11
10k
Ω
10k
Ω
H12
14
13
23
24
SH1
DDSP
CPU-A
CPU-B
KA
KB
white
brown
Screen connection
DDSP:
D
ouble
D
ynamic
S
afety
P
art with fault
monitoring of the actuator,
read head and the
cable to the read head
CES evaluation unit
Read head
Coded
actuator
Trans-
ponder
Illustration: Actuator not in the operating distance
TST
9.2.1. Self‑test with test input TST on page 14)
OUT
Door monitoring output (not a safety output)
ERR
Diagnostic output
GND
0 V (connected internally to 0 V for the operating voltage)
H11/H12
Read head connection
SH1
Read head shield connection
13/14
Connection for relay contact A, safety relay enable
23/24
Connection for relay contact B, safety relay enable