![EUCHNER CES-A-UBA-01 Operating Instructions Manual Download Page 22](http://html.mh-extra.com/html/euchner/ces-a-uba-01/ces-a-uba-01_operating-instructions-manual_2434754022.webp)
Operating instructions
Non-Contact Safety System CES-A-UBA-01/CES-A-UBA-01B
22
(Translation of the original operating instructions) 2097097-17-08/20
Technical data
Parameter
Value
Unit
min.
typ.
max.
Housing material
Fortron, reinforced thermoplastic, fully encapsulated
Dimensions
42 x 25 x 12
mm
Weight (incl. 10 m cable)
0.3
kg
Ambient temperature
-25
-
+70
°C
Degree of protection
IP67/IP69K
Installation orientation
Any
Method of operation
Inductive
Power supply
Via evaluation unit
In combination with actuator CES-A-BBA on evaluation unit CES-A-UBA-01
Assured release distance S
ar
-
-
23
mm
Actuating range for center offset m = 0
1)
- Switch-on distance
-
6
-
- Assured operating distance S
ao
5
-
-
- Switching hysteresis
0.5
1.5
-
In combination with actuator CES-A-BBA on evaluation unit CES-A-UBA-01B
Assured release distance S
ar
-
-
32
mm
Actuating range for center offset m = 0
2)
- Switch-on distance
-
15
-
- Assured operating distance S
ao
10
-
-
- Switching hysteresis
0.5
2
-
Minimum distance s for side approach direction
-
3
-
In combination with actuator CES-A-BDA-20 on evaluation unit CES-A-UBA-01
Assured release distance S
ar
-
-
24
mm
Actuating range for center offset m = 0
3)
- Switch-on distance
-
7
-
- Assured operating distance S
ao
6
-
-
- Switching hysteresis
0.5
1.5
-
Minimum distance s for side approach direction
-
1
-
Installation in steel, surface/flush
Assured release distance S
ar
-
-
24
mm
Actuating range for center offset m = 0
- Switch-on distance
-
4.4/3.6
-
- Assured operating distance S
ao
3.6/3
-
-
- Switching hysteresis
0.4/0.3
1.2/1.0
-
Minimum distance s for side approach direction
-
1
-
Installation in stainless steel, surface/flush
Assured release distance S
ar
-
-
24
mm
Actuating range for center offset m = 0
- Switch-on distance
-
4/3.3
-
- Assured operating distance S
ao
3.3/2.7
-
-
- Switching hysteresis
0.4/0.3
1.1/0.9
-
Minimum distance s for side approach direction
-
1
-
In combination with actuator CES-A-BDA-20 on evaluation unit CES-A-UBA-01B
Assured release distance S
ar
-
-
33
mm
Actuating range for center offset m = 0
3)
- Switch-on distance
-
16
-
- Assured operating distance S
ao
11
-
-
- Switching hysteresis
0.5
2
-
Minimum distance s for side approach direction
-
4
-
Connection
M8 plug connector, 3-pin
Connecting cable
-
-
25
m
1) These values apply to flush installation of the read head and the actuator in aluminum.
2) These values apply to surface installation of the read head and the actuator.