![EUCHNER CES-A-UBA-01 Operating Instructions Manual Download Page 32](http://html.mh-extra.com/html/euchner/ces-a-uba-01/ces-a-uba-01_operating-instructions-manual_2434754032.webp)
Operating instructions
Non-Contact Safety System CES-A-UBA-01/CES-A-UBA-01B
32
(Translation of the original operating instructions) 2097097-17-08/20
11.9. Actuator CES-A-BMB
Ì
Cylindrical design M12 x 75
Ì
In combination with read head CES-A-LMN-SC
(actuating range on request for read head CES-A-LNA…/LCA…)
Dimension drawing
11
0,80
6
M
12
x0
,7
5
Active face
NOTICE
Ì
The actuator can be screwed into the M12 x 0.75 thread provided with the aid of an insertion tool
(order no. 037 662).
Ì
Flush installation of the actuator in steel is permissible.
Technical data
Parameter
Value
Unit
min.
typ.
max.
Housing material
Stainless steel
Dimensions
M12 x 0.75, depth 6
mm
Weight
0.002
kg
Ambient temperature
-25
-
+85
°C
Degree of protection
IP67/IP69/IP69K
Installation orientation
Active face opposite read head
Power supply
Inductive via read head