![EUCHNER CES-A-UBA-01 Operating Instructions Manual Download Page 24](http://html.mh-extra.com/html/euchner/ces-a-uba-01/ces-a-uba-01_operating-instructions-manual_2434754024.webp)
Operating instructions
Non-Contact Safety System CES-A-UBA-01/CES-A-UBA-01B
24
(Translation of the original operating instructions) 2097097-17-08/20
Terminal assignment
Read head with connection cable
H11 H12 SH1
BN
WH
Shield
View on the plug
connector of the
read head
Evaluation unit
CES-A-UBA-…
Read
head
Technical data
Parameter
Value
Unit
min.
typ.
max.
Housing material
PE-HD plastic without reinforcement, fully encapsulated
Flat seal material
Fluororubber 75 FPM 4100
Dimensions
42 x 25 x 12
mm
Weight (incl. 10 m cable)
0.3
kg
Ambient temperature
-25
-
+50
°C
Degree of protection
IP67/IP69K
Installation orientation
Any
Method of operation
Inductive
Power supply
Via evaluation unit
In combination with actuator CES-A-BBA on evaluation unit CES-A-UBA-01
Assured release distance S
ar
-
-
23
mm
Actuating range for center offset m = 0
1)
- Switch-on distance
-
6
-
- Assured operating distance S
ao
5
-
-
- Switching hysteresis
0.5
1.5
-
In combination with actuator CES-A-BBA on evaluation unit CES-A-UBA-01B
Assured release distance S
ar
-
-
32
mm
Actuating range for center offset m = 0
2)
- Switch-on distance
-
15
-
- Assured operating distance S
ao
10
-
-
- Switching hysteresis
0.5
2
-
Minimum distance s for side approach direction
-
3
-
In combination with actuator CES-A-BDA-20 on evaluation unit CES-A-UBA-01
Assured release distance S
ar
-
-
24
mm
Actuating range for center offset m = 0
3)
- Switch-on distance
-
7
-
- Assured operating distance S
ao
6
-
-
- Switching hysteresis
0.5
1.5
-
Minimum distance s for side approach direction
-
1
-
Installation in steel, surface/flush
Assured release distance S
ar
-
-
24
mm
Actuating range for center offset m = 0
- Switch-on distance
-
4.4/3.6
-
- Assured operating distance S
ao
3.6/3
-
-
- Switching hysteresis
0.4/0.3
1.2/1.0
-
Minimum distance s for side approach direction
-
1
-
Installation in stainless steel, surface/flush
Assured release distance S
ar
-
-
24
mm
Actuating range for center offset m = 0
- Switch-on distance
-
4/3.3
-
- Assured operating distance S
ao
3.3/2.7
-
-
- Switching hysteresis
0.4/0.3
1.1/0.9
-
Minimum distance s for side approach direction
-
1
-
In combination with actuator CES-A-BDA-20 on evaluation unit CES-A-UBA-01B
Assured release distance S
ar
-
-
33
mm
Actuating range for center offset m = 0
3)
- Switch-on distance
-
16
-
- Assured operating distance S
ao
11
-
-
- Switching hysteresis
0.5
2
-
Minimum distance s for side approach direction
-
4
-
Connecting cable
Hard-wired encapsulated connection cable, with crimped ferrules
PVC,
∅
4.6 mm
Cable length
-
-
25
m
1) These values apply to flush installation of the read head and the actuator in aluminum
2) These values apply to surface installation of the read head and the actuator.
3) These values apply to non-metallic surrounding material. Other materials on request.