![EUCHNER CES-A-UBA-01 Operating Instructions Manual Download Page 28](http://html.mh-extra.com/html/euchner/ces-a-uba-01/ces-a-uba-01_operating-instructions-manual_2434754028.webp)
Operating instructions
Non-Contact Safety System CES-A-UBA-01/CES-A-UBA-01B
28
(Translation of the original operating instructions) 2097097-17-08/20
With evaluation unit CES-A-UBA-01B and actuator CES-A-BMB
-4
-6
-2
0
Centre offset m [mm]
Distance s [mm]
OFF
ON
Switch-on
distance
ON
OFF
Hysteresis
Distance s
S
ao
Output state
Switch-off
distance
OFF
-8
2
8
6
4
2
4
6
8
Actuator
Read
head
s
m
not permissible area
not permissible area
Hysteresis
NOTICE
A minimum distance of s = 1.2 mm must be maintained.
Terminal assignment
Read head with plug connector
H11 H12 SH1
1
3
4
BN
WH
Shield
View on the plug
connector of the
read head
Evaluation unit
CES-A-UBA-…
Technical data
Parameter
Value
Unit
min.
typ.
max.
Housing material
Nickel-plated CuZn housing sleeve
Plastic PBT GF20 cap
Dimensions
M12 x 1, length 38
mm
Weight (incl. 10 m cable)
0.2
kg
Ambient temperature
-25
-
+85
°C
Ambient pressure
(only of active face in installed condition)
-
-
10
bar
Degree of protection
IP67/IP69/IP69K
Installation orientation
Any
Method of operation
Inductive
Power supply
Via evaluation unit
In combination with actuator CES-A-BMB on evaluation unit CES-A-UBA-01
Assured release distance S
ar
-
-
8.5
mm
Actuating range for center offset m = 0
1)
- Switch-on distance
-
2.5
-
- Assured operating distance S
ao
1.6
-
-
- Switching hysteresis
0.2
0.3
-
In combination with actuator CES-A-BMB on evaluation unit CES-A-UBA-01B
Assured release distance S
ar
-
-
10
mm
Actuating range for center offset m = 0
1)
- Assured release distance S
ar
-
-
10
- Switch-on distance
-
5
-
- Assured operating distance S
ao
3.5
-
-
- Switching hysteresis
0.1
0.3
-
Connection
M8 plug connector, 3-pin
Connecting cable
-
-
15
m
1) These values apply to surface installation of the read head in steel.