Pre-Installation Checks
1. Ensure the input supply switch on the Controller is switched
OFF.
2. Ensure the correct AT-XXXX fixture is fitted to the MINIRAY Hand Tool (See “Fitting an ATXXXX
Fixture” Page 17.)
3. Connect the MINIRAY Hand Tool to the Controller and secure the locking ring.
4. Connect the mains supply cable to the Control
5. Plug the mains supply cable into the electricity supply socket.
Selecting the Hand Tool Aperture
Two MINIRAY Hand Tool types are available the difference between models is the aperture size:
• IR-1759 - Standard
• IR-3104 - Large
A kit (AE-897) is available to convert between standard and large aperture sizes.
The kit contains the relevant optical block, inner reflector, optical filter and locking ring.
See
Pg. 30 Spare Parts and Accessories
for ordering information.