4. Installation
Unpacking
Remove any packaging and inspect the IR1759-MK5 MINIRAY Heat Tool for any damage. Check
that all items have been supplied.
Report any damaged parts or missing items to your supplier.
Retain all packing materials. These will be required if you need to return the item for repair.
Location/Positioning
The IR1759-MK5 MINIRAY Heat Tool is designed to be installed and operated in an industrial
environment. However, it should not be used near explosive or flammable materials or in a location
where it would be subject to moisture or excessive dust.
Parts of the Mini-ray Hand tool get hot during use. Special care must be taken to avoid heating ma-
terials other than the pieces being worked on.
The tool has an IP1.1rating.The mini ray tool is designed for areas free from inflammable
solids, liquids and gases.
The MINIRAY
System should be located on a bench with a level firm surface with sufficient
clearance must be left at the rear of the unit, for connection to the mains supply and the
MINIRAY Hand Tool. Controllers are supplied with a 2.5m mains lead and Hand Tool with a
3.1m control lead
Mains electrical leads should be routed to help prevent damage or entanglement.
Work in areas with good lighting.
Never use the tool near solids, liquids or gases that burn easily.
The tool shall be maintained well.
Electrical connections. Ref photo page 10.
The mini-ray system must be installed in accordance
with established safe working practices. Incorrect use can cause injury.
Installation requirements must conform to local standards and regulations
WARNING!
Breathing difficulties / suffocation due to hazardous fumes.
Depending on the product, harmful fumes can be produced during the shrinking
and soldering procedure.
Pay attention to the product's safety data sheet.
The working area should be well-ventilated.
If necessary, install an air extraction system.
The Mini –Controller is a Class I tool. This controller is designed to operate from a 230V±10% 50Hz
mains and 110v 60hz mains
For example:ED-7-CONT-230/110V & -MK5.
The Mini Ray System is supplied with an appropriate power lead / plug at one end and an IEC
connector at the other.
If this mains lead is lost at any time it should only be replaced with a CE / UL approved mains power
supply cord.
The mains supply to the equipment must be protected by a 30mA residual current device
4.1 Installation and Set-Up