ES4441.1 Compact Error Simulation Module with Breakout Frontpanel - User´s guide
22
Introduction
ETAS
PINCONTROL
PINCONTROL provides an easy-to-use user interface in which all errors can be
activated and reset.
PINCONTROL has, in particular, the following features:
• Creating and managing failure sets. A failure set is a group of ECU signals
(e.g. all signals of the oxygen sensor)
• Signal lists with all signals of a selected failure set. This is where the signal
is selected for which an error is to be simulated.
• Display of all available errors for a selected signal in one window
• Errors are selected in this window by mouse click
• Settings of the desired error duration
• Triggering the error by mouse click
• Configuration of the Ethernet interface
• Configuration for master/slave operation
2.3
Block Diagram
The following figure shows a principle overview of the jumpers, the error swit-
ches and the connectors of the ES4441.1 Compact Error Simulation Module
Abb. 2-3
Block Diagram of the ES4441.1 Compact Error Simulation Module
3A
15A
20A
1
40A
Rail1
Rail2
Load
IMESS1
IMESS2
LC1
LC2
7,5A
+UBATT1
- UBATT1
+UBATT2
- UBATT2
LOAD (1)
ECU (1)
LOAD (2)
ECU (2)
1A
ECU
3
2
31
15
202
1A
13
20A
1