Mechanical Construction
ETAS
5.5
Safety Measures
The over current protection of the 15A, 20A and 40A channels of the ES4441.1
Compact Error Simulation Module is realised by fuses. These are standard blade
fuses used commonly in the automotive environment.
5.5.1
Overview Fuses:
Be sure to use only the following fuses:
The following table shows the assignment of the Fuses to the error channels of
the ES4441.1.
The fuses have sockets and can be replaced easily. The fuse compartment has a
1 mm aluminum cover. The mounting position of the fuse holders in use com-
partment is shown in the following figure.
Type
Littelfuse MINI Blade Fuse 32 V
Voltage rating
32 V
Part numbers
0297015 (15 A)
0297020 (20 A)
CAUTION!
To avoid injury and damage, observe the following: Only use the silver
plated and certified variant of the above described fuses.
Fuse*
Function
Specification
F1
Protects channel 326
15 A
F2
Protec ts channel 328
15 A
F3
Protects channel 332
20 A
F4
Protects channel 330
20 A
F5
Protects channel 338
20 A
F6
Protects channel 339
20 A
F7
Protects channel 340
20 A
F8
Protects channel 340
20 A
* For details on the position of the fuses, please refer to the figure in
the section "To change fuses" on page 60.
F1
F2
F3
F4
F5
F6
F7
F8
15A
15A
20A
20A
20A
20A
20A
20A