47
Advanced features
Tamper alarms.
Beam tamper in closed position.
User manual reference -
Page 22
In cases where the safety beams have been tampered with, the safety protocols will still allow the gates to open but will not allow the gates to close.
This safety feature can be turned into a security risk by anyone with ill intention. The safety beam input tampering alarm feature gives you a ealry
warning of any tampering that may have occured while you were away from the property. If the gates are in the closed position and the safety beam
input is trigger for longer than 20 seconds, then the alarm output will become active. This output would usually be connected to a visual warning
device such as a light or to a zone on the household alarm system.
In the case of a light being used, on approach to the entrance the user is alerted to the attempt to compromise their security. Our advice is that the
user not trigger the gates to open, in this situation, but rather to continue driving to their nearest armed response standby point or to the nearest
police station. This way they can ask for an escort onto the property.
Safety beam alarm mode is available in all modes of operation so long as a set of safety beams is installed.
Action
Response
Safety beam equipment
tampered with while
gates are in the closed
position.
Alarm output
remains in
standby status.
20 seconds after safety
beam equipment has
been tampered with.
Alarm output
activates.
Safety beam equipment
returned to normal
functioning status.
Alarm output
returns to
standby.
Gate closed.
Off
0
20 sec.
On/off...
Built in buzzer sounding
can be disabled.
On
Off
Advanced features
Gate kept open too long alarm.
User manual reference - Page
In a cases where the user would like to be notified of the gate being kept open for longer than a predetermined time period, the gate jammed open
alarm can be setup. The alarm condition will reset to off when the gate is closed again.
Action
Response
Gate prevented from
closing.
Alarm output
remains in
standby status.
After programmed gate
jammed open time.
Alarm output
activates.
Gate returns to full
closed position.
Alarm output
returns to
standby.
Off
0
20 sec.
On/off...
Built in buzzer sounding
can be disabled.
On
Off