91
random functions
14 random functions
The LokSound 5 can be up to 8 functions randomly off solve. It can be
connected not only noise but also logical functions or physical outputs. Each
random function is now initiated as a (randomly controlled) button on the
controller. Thus the whole works, a function key in the Function mapping needs
to be defined for each releasable at random function. This usually is anyway
always the case. The following parameters can cut overall for each random
function be set:
• What is the function key (F0 to F31) to be triggered.
• Whether the random function in, route, or both should be triggered.
• Whether the random function should only be triggered when the driving noise
(main sound) is on.
• The minimum and maximum on the random function. The actual on-the decoder
calculated randomly between these two values.
• The minimum and maximum break time for this random function. In practice, this
value defines the time "distance" before the random function will be triggered
again. The following table shows the values in which CVs geschrie- must be
require to gure correctly config- the random functions:
value range
Random function CV 32 configuration function
button
In the prior case
Only ride with vehicle
noise
Switch-Min.
Switch-Max.
Pause time
min.
Pause time
Max.
Random function 1
13
CV 257
0-31
+ 64 +128
+ 32
CV 258
CV 259
CV 260
CV 261
Random function 2
13
CV 265
0-31
+ 64 +128
+ 32
CV 266
CV 267
CV 268
CV 269
Random function 3
13
CV 273
0-31
+ 64 +128
+ 32
CV 274
CV 275
CV 276
CV 277
Random function 4
13
CV 281
0-31
+ 64 +128
+ 32
CV 282
CV 283
CV 284
CV 285
Random function 5
13
CV 289
0-31
+ 64 +128
+ 32
CV 290
CV 291
CV 292
CV 293
Random function 6
13
CV 297
0-31
+ 64 +128
+ 32
CV 298
CV 299
CV 300
CV 301
Random function 7
13
CV 305
0-31
+ 64 +128
+ 32
CV 306
CV 307
CV 308
CV 309
Random Function 8
13
CV 313
0-31
+ 64 +128
+ 32
CV 314
CV 315
CV 316
CV 317
The on-times and pause times may be from 0-255 sec- onds (unit: 1 second)
can be given. The value for the configuration-CV is as follows: Addie- ren to the
desired function key as a numerical value (light button counts as "0") the value of
32, 64 and 128, depending on when the random function to be triggered. For
example, the random function should trigger 3 F13, and only when the running
noise is active and the locomotive is. therefore, write the value in the CV 273 (13
+ 32 + 64 = 109). Please set the index register CV 31 to 16 and CV 32 to 13
before changing values. Note the following:
• Each random function is independent of the other functions Zufallsfunk-. Also,
several random functions be active at a time, then.
• If the minimum and the maximum pause time are set to the same value,
triggering a steady beat at the same will be done.
• If the minimum and maximum turn be set equal to the random function will be
triggered always the same length.