39
Figure 28: RC servos to LokSound 5 XL
Servo1
(AUX15)
Servo2
(AUX16)
Servo3
(AUX17)
Servo4
(AUX18)
6.10.8. Suitable smoke generators
Unfortunately, it is not easy to find suitable smoke generators for any purpose.
Whether the amount of smoke generated depends on the following factors:
a) rail stress
Depending on the command station track voltages are different heights. It is
therefore possible that a locomotive not smoke when used on a central
office, on the other. Even 1V variation makes a big difference.
b) the type and tolerance of the Seuthe®-smoke generator and the smoke distillate
The Seuthe®-smoke generators have considerable tolerances
Fertigungstole-. Therefore, there is another identical construction may be that
one works perfectly well, is not. Art and filling level of the smoke distillate are
also influential factor.
c) Setting the decoder output For correct smoking action you should set the AUX
output to "Dimmer" full "Brightness". For details, see Chapter 12th
d) Connecting the smoke
Most smoke generators are tet geschal- against the chassis. Therefore the
smoke has power only every second half-wave on the track. It now depends
on your digital from central and the protocol used, how much power gets to
the smoke. The normally recommended for digital mode Seuthe® 11 receive
too little juice and do not smoke (properly).
There are two possible solutions to this problem: Solution 1: Use of a Seuthe®
No 10. This is intended for operating Analogbe- and is relatively draw much
power from the decoder.. Depending on the tolerance can it happen that the
overcurrent protection responds the decoder output. In this case, either a relay
(ESU no. 51963) In applications or slightly reduce the "brightness" of the output.
6.10.6.2 servo outputs on the LokSound 5 XL
For the servo outputs 1 to 4 at 5 LokSound XL is respectively an appropriate
3-pin connector is provided. Pay attention to the polarity when connecting the
servos.
6.10.7. SUSI / power / logic outputs
The existing at each LokSound decoder 5 lines for the SUSI interface may
alternatively be configured as a servo outputs or logic outputs. In this way, the
number of available outputs can be increased.
Please keep in mind that existing in 21MTC, Next18 or PluX- interfaces SUSI
pins currently according to the standard may not be used otherwise shared.
Therefore, you must always consider how these pins on the crucial indicator
(or adapter board) are connected.
Installing the decoder
GND
+ 5V IMP
GND
+ 5V IMP
GND
+ 5V IMP
GND
+ 5V IMP
Summary of Contents for 58315
Page 104: ...104 notes...
Page 105: ...105 notes...
Page 109: ...109 notes...
Page 110: ...110 notes...
Page 111: ...111...