Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
28
!
!
!
!
!
Operating Commands
To
Type
Log in
login, MASTERCODE
Insert a User
in, USER, PIN [,OPTIONS]*
Modify a User
mo, USER, PIN [,OPTIONS]*
Delete a User
de, USER
Insert the Temp Code
in, tmp, PIN, EXPTIME [,OPTIONS]*
Modify the Temp Code
mo, tmp, PIN, EXPTIME [,OPTIONS]*
Delete the Temp Code
de, tmp
List a User
le, USER (or “tmp” for Temp Code)
List all Users
la
List all Users paged
lp
List Keypad configuration
lc
Exit program
ex
*[,OPTIONS]= option numbers with no commas between them.
Example: Type mo,5,555,13 to change User 5 code to 555 and give
Latching and Output A authorization.