Code
Standby Mode Normal Operation
213 # Dim
Dim
214 # Dim
Bright
5.
Remove power.
6.
Remove configuration jumper.
7.
Re-apply power.
8.
Press PROGRAM button in the ERM to establish the encoded
connection. This will put the system into setup mode.
9.
Press * * to exit.
CAUTION
: This procedure completely erases the memory and
restores factory defaults! Once the memory is cleared, all pro-
grammed User Codes are erased and factory default settings
are restored.
Keypad Reset
In certain cases you may want to erase all user codes and restore
system defaults. To perform this procedure:
1.
Remove power.
2.
Jumper the two pins above the connector labeled "CONFIG".
3.
Apply appropriate power. (You should hear 4 beeps and the
RED LED will flash and the GREEN LED will be solid).
IMPORTANT
: Once the configuration is selected, you must re-
move power, remove the configuration jumper and then re-apply
power in order to complete the configuration procedure. Note: If
the configuration jumper is not removed, the LED's will flash and
the Keypad will beep continuously.