20
!
Internal Alarm
1) Enter
5 #
2) Enter the desired Door Ajar Time (1-99 seconds), follwed
by
#
Example:
5 # 5 # 1 0 #
(Sets Internal Door with 10 second Door Ajar Time)
!
Master Code Door Unlock Option (Default: Allow)
a. Enter
6 #
b. Enter
0 #
to prevent the master code from unlocking the door.
c. Enter
1 #
to allow the master code to unlock the door.
d. Return to Step 3 or enter
* *
to exit programming.
!
Time Clock Input (Default: Prevent)
a. Enter
7 #
b. Enter
0 #
to prevent lockout
c. Enter
1 #
to lockout all users that do not have 24 hour option
enabled.
d. Return to Step 3 or enter
* *
to exit programming.
!
Baud Rate (if using Keypad with Encoded Relay Module)
a. Enter
8 #
b. Enter
0 #
to set Baud Rate to 2400
c. Enter
1 #
to set Baud Rate to 9600 (default)
4. Enter
* *
to complete the sequence and reset the system to normal
operation.
Note:
If using a printer or Hyper-terminal,
0 #
will print Setup Configuration