10
Normal System Operation
When the system is first powered up (or when communication is
broken between the Keypad and the ERM3 module), the PRO-
GRAM button in the ERM must be pressed to establish the
encoded connection. This also puts the system into setup mode.
To end, press * * to exit. Or, the system will automatically exit
programming if no entries are made for 30 seconds.
!
!
!
!
!
Keypad LED Status Indicators
!
A flashing green LED indicates that the door is unlocked (mo-
mentarily).
!
A solid green LED indicates that the door is unlocked (latched).
!
A solid red LED indicates that the door is locked.
Depending on how the System Options are configured, User
Commands are used to operate Manual Latching. The User
Commands are trailing digits entered after an authorized user
code. The ability to use these User Commands depends on
authorizations assigned to each User (see page 13 or pages 21-
22).
As the Main Output activates, the green LED will flash for 5
seconds. While the green LED is flashing, enter one (or more) of
the following User Commands:
0 #
to Latch the Door Closed (Main Relay, 2
nd
Door or 3
rd
Door)
1 #
to Latch the Door Open (Main Relay, 2
nd
Door or 3
rd
Door)
2 #
to Turn Output A OFF (2
nd
Output as Aux.)
3 #
to Turn Output A ON (2
nd
Output as Aux.)
4 #
to Turn Output B OFF (3
rd
Output as1 Aux.)
5 #
to Turn Output B ON (3
rd
Output as Aux.)
○ ○ ○ ○ ○