CLEARANCES TO NON-COMBUSTIBLES
Non-combustible surfaces are defined as brick, metal, marble, concrete etc., and also a
number of man-made materials impervious to flame. If in doubt refer to the material
manufacturer for further information, before proceeding with installation.
It is recommended that there is at least 400mm (16”) clearance above the outlet grille.
Minimum clearance from the bottom of the outer frame to the floor must be 90mm
(3.5”).
Clearance to the sides of the heater is 50mm (2”), however, clear and easy access to the
controls located on the lower right hand side of the heater behind the front panel on
the right hand side must be allowed for, and we would therefore recommend that at
least 100mm (4”) be allowed.
Clearance to the front of the heater is 500mm (2ft). Care must be taken that no brickwork
or other incombustible material protrudes into the area immediately around the base
of the heater or area underneath the heater in a way that is likely to affect natural airflow
into or around the heater.
CLEARANCES TO COMBUSTIBLE MATERIALS
Combustible materials are defined as wood, fabrics, or other materials likely to combust
if exposed to flame. Generally, any material, which is likely to discolour, melt or misshape
when exposed to moderate heat, should be considered as a combustible material of
surface. Any fire surround or shelf to be used in conjunction with this heater should be
rated at a minimum of 100°C otherwise discolouration or smells may occur. If in doubt
refer to the shelf manufacturer.
Minimum clearance from the bottom of the outer frame to the floor must be 90mm
(3.5”).
If fitting the heater with optional floor stand or in the corner
configuration with optional floor stand see figures 4 & 5A for heights.