VENTILATION
Purpose provided ventilation of 100cm2 is required for this heater. This ventilation must
never be blocked or partially blocked. An openable window or equivalent is also
required. Ventilation fitted under, or within immediate vicinity of the heater must not be
used as it may adversely affect performance of the combustion monitoring system (ODS)
system.
The requirements of other appliances operating in the space or room must be taken
into consideration when assessing ventilation requirements. This will have been carried
out by your Gas Safe registered installer.
A supply of fresh air into the room is advisable to maintain temperatures within limits.
The heater MUST NOT be installed in a bedroom, bathroom or any sleeping area.
Additionally for L.P.G. – the heater must not be used in cellars or basements.
BURNER ARRANGEMENT
The burner should only be used with vermiculite granules as shown in the Installation
Instructions. The heater must only be fitted with the vermiculite supplied. DO NOT add
any extra logs or coals.
OPERATING THE HEATER
The heater is fitted with a pilot light which is also an oxygen depletion sensor (ODS),
piezo spark and flame sensing device. The control is located behind the front panel on
the lower right hand side. The pilot light is located at the right hand end of the burner.
Should the heater be extinguished for any reason wait 3 minutes before re-ignition is
attempted. The heater should not be used at a lower setting than the ‘LOW’ position.