Page 34
39P-I01-160617
It is recommended that the pilot light be left ‘on’ even if the main burner
is turned ‘off’.
BATTERY REPLACEMENT
When the receiver batteries need changing, frequent bleeps can be heard for three
seconds when the motor turns.
Ensure the appliance is cold, and remove the receiver box from underneath the
appliance and replace the batteries with 4 X 1.5 volts “AA” type quality alkaline
batteries.
If the remote control unit ceases to work. The 9 volt battery should be changed with a
new 9 volt quality alkaline battery. Replacement is recommended every two years.
Mains electrical power is not required as this system runs on batteries
only (Alkaline recommended). Battery information: Handset – 1 x 9V
block, Receiver – 4 x 1.5V AA.
COMBUSTION MONITORING SYSTEM
This heater is fitted with a combustion monitoring safety device (ODS). If the heater shuts
off during use for no apparent reason then several reasons may be suspected. If a door
or window has been opened creating a draught, then pilot disturbance could be the
problem and removal of the draught should resolve this. The heater can then be re-lit in
accordance with the previous section.
If pilot disturbance is not the cause, then the ODS safety system may be in operation.
Switch the heater OFF; call in your installer to check the heater and ventilation.
Remedial work must be carried out as required. DO NOT allow the heater to be used
until the heater and installation is passed as safe. If the pilot continues to be
extinguished, you must call your installer to check the operation of the complete
heater.
Summary of Contents for 39 Portrait
Page 37: ...Page 37 39P I01 160617...
Page 38: ...Page 38 39P I01 160617...
Page 39: ...Page 39 39P I01 160617...