Page 8
39P-I01-160617
The heater may be mounted directly onto a combustible wall.
Clearance to the sides of the heater is 100mm (4”) but curtains, drapes and other fabrics are
not permitted within a distance of 500mm (20”) of the heater sides. No such materials
are permitted directly above the heater regardless of distance.
Clearance to the front of the heater is 1000mm (39in).
The minimum clearance to the ceiling above the top of the outer grille must be at least 1067mm
(42”)
A combustible shelf may be fixed to the wall above the heater, providing that it
complies with the dimensions given below
Under no circumstances must any electrical device (e.g. Flat Screen T.V.)
be wall mounted above this fire.
The shelf depth may be increased up to a maximum of 457mm (18”) but the height must also
be increased accordingly. An increase in height of 25mm is required for every 12.5mm of
additional shelf depth. For shelves that are too low, protective devices can be used such
as metal heat deflectors, but it must be assured that the shelf does not reach an
unacceptable temperature before relying on such a solution.
Maximum depth of shelf
Minimum distance from top of
outlet grille to underside of shelf
75mm (3 inches)
305mm (12 inches)
150mm (6 inches)
457mm (18 inches)
457mm (18 inches)
1067mm (42 inches)
As with all heating appliances, any decorations, soft furnishings, and all coverings (i.e.
flock, blown vinyl and embossed paper) positioned too close to the heater may discolour
or scorch.