Chapter 4 Operation
48
Step 1 Setup
3. Step selection
Input “1” as the step No. and press the
ENT.
key. Then, press the
NEXT
key.
Step No.
:
Changes the value.
ENT.
:
Enters the selection.
* Setting range : 1
≦
Step number
≦
9
Stands for
“
Step
”
○
PRGM SET
Press the
NEXT
key and move to the next setting.
4
Temperature (Humidity) link control status ON/OFF
Select “ON” and press the
ENT.
key. Then, press the
NEXT
key.
Temperature (humidity) link control status
:
ON
Turns temperature (humidity) link control
ON. Go to the target temperature setting
(step 5 in this procedure).
OFF
Turns temperature (humidity) link control
OFF. Go to the exposure time setting
(step 8 in this procedure).
ENT.
:
Enters the selection.
Stands for
“
Control
”
○
PRGM SET
•
Turning temperature (humidity) control OFF means basing
that step entirely on the set exposure time. When the time
set for that step elapses, the cabinet will advance the
program to the next step, therefore this feature can be
used as a timer.
Press the
NEXT
key and move to the next setting.