– 77 –
C420e
8
FAULT TRACING
Try these recommended checks and inspections before sending for an authorised service technican.
Type of fault
Actions
No arc
S
Check that the mains power supply switch is turned on.
S
Check that the welding current supply and return cables are
correctly connected.
S
Check that correct current value is set.
Welding current is interrupted
during welding
S
Check whether the thermal overload trip has operated
(indicated by the orange lamp on the front).
S
Check the main power supply fuses.
Thermal overload trips
operate frequently
S
Check to see whether the air filters are clogged.
S
Make sure that you are not exceeding the rated data for the
power source (i.e. that the unit is not being overloaded).
Poor welding performance
S
Check that the welding current supply and return cables are
correctly connected.
S
Check that the correct current value is set.
S
Check that the correct welding wires are being used.
S
Check the main power supply fuses.
S
Check the wire feed unit – if proper rolls are applied and
properly set the pressure of the wire feeder’s pressure rollers
9
ORDERING OF SPARE PARTS
ESABMig C420 is designed and tested in accordance with the international and Euro-
pean standards IEC/EN 60974–1 and EN 50199. It is the obligation of the service unit
which has carried out the service or repair work to make sure that the product still
conforms to the said standard.
Spare parts may be ordered through your nearest ESAB dealer, see the last page of
this publication.
GB
Summary of Contents for Mig C420
Page 9: ... 9 C420s 5 3 Elektrisk installation SE ...
Page 24: ... 24 C420d 5 3 Elektrisk installation DK ...
Page 39: ... 39 C420n 5 3 Elektrisk installasjon NO ...
Page 54: ... 54 C420x 5 3 Sähköasennus FI ...
Page 69: ... 69 C420e 5 3 Electrical installation GB ...
Page 84: ... 84 C420g 5 3 Elektrische Installation DE ...
Page 99: ... 99 C420f 5 3 Installation électrique FR ...
Page 114: ... 114 C420h 5 3 Elektrische installatie NL ...
Page 129: ... 129 C420c 5 3 Instalación eléctrica ES ...
Page 144: ... 144 C420i 5 3 Impianto elettrico IT ...
Page 159: ... 159 C420p 5 3 Instalação eléctrica PT ...
Page 168: ... 168 TOCy 0 0 1 2 3 3 3 2 456789 0 0 0 456789 0 0 A 3 ...
Page 173: ... 173 C420y 8 Z D E 2 2 E Z C 2 2 3 A 1 1B 2 3 D A3 6 0 3174 F0 2 3 2 3 3 1 3 3 ...
Page 174: ... 174 C420y 7 52 5 502 20 ...
Page 189: ...C420o 189 8 9 PL ...
Page 204: ...C420j 204 CZ ...
Page 218: ...C420u 218 H 9 g HU ...
Page 227: ... 227 ...
Page 230: ...C420di 230 ESABMig C420 C420w ...
Page 232: ...C420di 232 ESABMig C420s C420sw ...
Page 235: ... 235 ...
Page 237: ...ESABMig C420 C420w C420s C420sw Edition 030801 C420we 237 ...