– 75 –
C420e
6.4.2
Synergy control mode
In synergy control mode, the operator first has to preselect material/gas [19] and
wire diameter [20].
While changing the voltage (with the voltage selectors [2,3]) digital instrument [14]
and lamps [17,18] on the front panel show welding parameters.
Synergy status lamp [17] is green (only in synergy mode) when correct welding
parameters are set, or red when incorrect or not allowed welding parameters are set
(then machine operation is disabled!).
Note:
Lamp is also red (in all control modes):
S
if during welding (gun trigger pressed) – any voltage selector [2, 3]
is operated, then the operation of the machine is disabled immediately until
the trigger is released,
S
when the gun trigger is pressed while turning on the machine with switch [1].
One of the lamps [18] points at recommended current outlet (–) with appropriate
inductance [9,10,11].
Digital display [14] shows values depending on display selectors [15, 16]
and machine status.
Before welding start: the upper display shows expected values of welding current [A]
or voltage [V] (both only in SYNERGY mode); the lower display shows wire speed
reference [m/min] or recommended maximum thickness [mm] of workpiece.
During welding: upper display shows actual welding voltage or current, the lower
display – as above.
After welding stop: the upper display shows last memorised (HOLD) values of
voltage or current (dimmed display).
Wire speed is set by program (stored in the microprocessor) and the knob [12] shall
be set to middle position ”0”. If necessary the operator may correct the preset speed
reference with that knob within
+/–
20% of the set value.
The ESABMig C420s/C420sw include program for two types of cored wires,
designed for welding with positive polarity:
S
OK Tubrod 1514 –
φ
1,2mm
S
OK Tubrod 1413 –
φ
1,2mm
To select those wires set synergy switch [19] to position FCW – Ar2CO
2
and set
knob [20] to 1,6mm for ESAB Tubrod 1514 or to 1,2mm for OK Tubrod 1413.
GB
Summary of Contents for Mig C420
Page 9: ... 9 C420s 5 3 Elektrisk installation SE ...
Page 24: ... 24 C420d 5 3 Elektrisk installation DK ...
Page 39: ... 39 C420n 5 3 Elektrisk installasjon NO ...
Page 54: ... 54 C420x 5 3 Sähköasennus FI ...
Page 69: ... 69 C420e 5 3 Electrical installation GB ...
Page 84: ... 84 C420g 5 3 Elektrische Installation DE ...
Page 99: ... 99 C420f 5 3 Installation électrique FR ...
Page 114: ... 114 C420h 5 3 Elektrische installatie NL ...
Page 129: ... 129 C420c 5 3 Instalación eléctrica ES ...
Page 144: ... 144 C420i 5 3 Impianto elettrico IT ...
Page 159: ... 159 C420p 5 3 Instalação eléctrica PT ...
Page 168: ... 168 TOCy 0 0 1 2 3 3 3 2 456789 0 0 0 456789 0 0 A 3 ...
Page 173: ... 173 C420y 8 Z D E 2 2 E Z C 2 2 3 A 1 1B 2 3 D A3 6 0 3174 F0 2 3 2 3 3 1 3 3 ...
Page 174: ... 174 C420y 7 52 5 502 20 ...
Page 189: ...C420o 189 8 9 PL ...
Page 204: ...C420j 204 CZ ...
Page 218: ...C420u 218 H 9 g HU ...
Page 227: ... 227 ...
Page 230: ...C420di 230 ESABMig C420 C420w ...
Page 232: ...C420di 232 ESABMig C420s C420sw ...
Page 235: ... 235 ...
Page 237: ...ESABMig C420 C420w C420s C420sw Edition 030801 C420we 237 ...