10 TOOLS
0460 896 274
- 75 -
© ESAB AB 2013
10.8.1
Specify voltage/wire co-ordinates
In order to create a synergic line for the short-/sprayarc method, four co-ordinates are
required; for the pulsing method, two co-ordinates are required. These co-ordinates must
then be saved under separate weld data numbers in the weld data memory.
Short-/Sprayarc
•
Bring up the main menu and select the MIG/MAG method SHORT/SPRAY.
•
Key in the desired values for voltage and wire feed speed for the first co-ordinate.
•
Bring up the MEMORY menu and store the first co-ordinate on any number.
The four co-ordinates for a short-/sprayarc line can be saved as any numbers. When
supplied from the factory, they are saved as numbers 96, 97, 98 and 99.
A higher weld data number should contain higher values for voltage and wire feed speed
than the nearest preceding weld data number.
The welding parameters inductance and regulator type must have the
same value
in all
four weld data numbers.
•
Define the number of co-ordinates that are required and then proceed to the “Specify
valid wire/gas combination” section.
Pulsing
•
Bring up the main menu and select the MIG/MAG method PULSING.
•
Key in the desired values for voltage and wire feed speed for the first co-ordinate.
•
Bring up the MEMORY menu and store the first co-ordinate on any number.
A higher weld data number should contain higher values for voltage, wire feed speed,
pulse frequency, pulse amplitude and background current than the nearest preceding
weld data number.
The welding parameters pulse time, Ka, Ki and “slope” must have the
same value
in both
weld data numbers.
•
Define the number of co-ordinates that are required and then proceed to the “Specify
valid wire/gas combination” section.
10.8.2
Specify valid wire/gas combination
Position the cursor on the WIRE TYPE row and press ENTER.
Summary of Contents for Aristo U82
Page 1: ...Aristo Instruction manual 0460 896 274 GB 20130902 Valid from program version 1 15A U82 ...
Page 80: ...MENU STRUCTURE 0460 896 274 80 ESAB AB 2013 MENU STRUCTURE ...
Page 81: ...MENU STRUCTURE 0460 896 274 81 ESAB AB 2013 ...
Page 82: ...MENU STRUCTURE 0460 896 274 82 ESAB AB 2013 ...
Page 83: ...MENU STRUCTURE 0460 896 274 83 ESAB AB 2013 ...
Page 84: ...MENU STRUCTURE 0460 896 274 84 ESAB AB 2013 ...