-- 42 --
bi09d1e2
The entire welding data settings configuration saved in the welding data memory
(utilised memory positions 1--255) is now saved on the compact flash card in the
WeldData.awd file. The file is located in a folder called WData. WData is generated
automatically when you insert a memory card.
NB: If you have already saved welding data once and save again, the old file will be
overwritten without any warning. If you want to keep the old file, it must be renamed.
11.2 Recalling welding data from a memory card
The RECALL function recalls welding data from the WeldData.awd file, which is
located in the WData folder, to the welding data memory.
If you want to recall welding data with a different file name, or located in a folder
other than WData, use the recall function in the file manager (see the
10
”File
manager” section)
11.3 Deleting welding data from a memory card
The DELETE function clears welding data from the WeldData.awd file.
12
CONFIGURATION MENU
Main menu -- --> Auxiliary function meny -- --> Configuration menu
This menu contains the following submenus:
S
Language, see chapter ”Do this first”
1.2
.
S
Code lock, see chapter
12.1
.
S
Remote controls, see chapter
12.2
.
S
MIG/MAG defaults, see chapter
12.3
.
S
MMA defaults, see chapter
12.4
.
S
General defaults, see chapter
12.5
.
S
Multiple wire feeders, see chapter
12.6
.
S
Unit of length, see chapter
12.7
.
12.1 Code lock
Main menu -- --> Auxiliary function menu -- --> Configuration menu -- --> Code
lock
When the code lock is enabled and you are in the measure image, remote control or
the fast mode menu, a password (lock code) is required to leave these menus.
CODE LOCK
LOCK STATUS:
OFF
SET/CHANGE LOCK CODE
QUIT
ENTER