-- 44 --
bi09d1e2
This brings you to the keyboard display, where you can type in the lock code. After
each character press the PRESS KEY and confirm the lock code using the ENTER
key.
The following text box appears:
UNIT UNLOCKED!
If the lock code is incorrect, you will see an error message that gives the user the
option of trying again or returning to the original menu, i.e. the measure image or the
fast mode menu.
If the lock code is correct, all restrictions on moving to other menus are removed,
although the code lock remains enabled, which means that the user can leave the
measure image and fast mode menu temporarily, but when you return to them the
lock will be enabled once more.
12.1.2 Set / change lock code
In set/change lock code you can edit an existing lock code or enter a new one. A
lock code can consist of max. 10 letters or digits.
12.2 Remote control configuration
Main menu -- --> Auxiliary function menu -- --> Configuration menu -- --> Remote
control
A non CAN--bus connected remote control must be connected via a remote control
adapter. When connected, enable the remote control in the measure image under
the REMOTE soft key.
12.2.1 Forget override
Move the cursor to the line
for FORGET OVERRIDE
MIG/MAG -- REMOTE CONTROLS
for FORGET OVERRIDE.
Press ENTER to call up a
list of options.
FORGET OVERRIDE:
DISABLE
DIGITAL OP:
5--PROG
ANALOG 1:
VOLTAGE
ANALOG 2:
WIRE SPEED
RANGE OF INPUTS:
ANALOG 1, DIG +/--
MIN
--10.0 V
MAX
10.0 V
ANALOG 2
MIN
1.5 m/min
MAX
25.0 m/min
QUIT
ENTER
When the ”Forget override” function is ”enable”, an automatic recall of last recalled
memory will be performed before each new weld starts. This is to eliminate the result
of all weld data tuning that has been done during the last weld procedure.