-- 23 --
bi09d1e2
5.2.2
LiftArc
With LiftArc
t
the arc is struck when the electrode is lifted from the workpiece.
Striking the arc using the LiftArc
t
function. Step 1: the electrode is touched on to the workpiece. Step
2: the trigger switch is pressed, and a low current starts to flow. Step 3: the welder lifts the electrode
from the workpiece: the arc strikes, and the current rises automatically to the set value.
-- LiftArc
t
is enabled in the
main menu
.
5.2.3
2--stroke
Gas pre--flow
Slope
up
Slope down
Gas post--
flow
Functions when using 2--stroke control of the welding torch.
In 2--stroke control mode, pressing the trigger switch starts gas pre--flow (if used)
and strikes the arc (1). The current rises to the set value (as controlled by the slope
up function, if in operation). Releasing the trigger switch (2) reduces the current (or
starts slope down if in operation) and extinguishes the arc. Gas post--flow follows if it
is in operation.
-- 2--stroke is enabled in the
measure image or the main menu
.
5.2.4
4--stroke
Gas pre--flow
Slope
up
Slope down
Gas post--
flow
Functions when using 4--stroke control of the welding torch.