-- 61 --
bi09d1e2
Error
code
Description
9
--15V power supply, (power unit)
The supply voltage is too high or too low.
Action:
Call a service engineer.
9
+20V power supply, (wire feeder)
The supply voltage is too high or too low.
Action:
Call a service engineer.
10
+15VB power supply, (Mig 4500i)
The supply voltage is too high or too low.
Action:
Call a service engineer.
10
+24VB power supply, (Mig 4000i/Mig 5000i)
The supply voltage is too high or too low.
Action:
Call a service engineer.
11
Wire speed
The wire speed is deviating from the preset value.
When this error occurs, the wire feed process stops.
Action:
Call a service engineer.
12
Communication error (warning)
The load on the system’s CAN bus is too high at the moment.
The power source/wire feeder might have lost contact with the controller.
Action:
Check the equipment to make sure that everything is properly connected.
If the error persists, call a service engineer.
14
Communication error
The system’s CAN bus has temporarily stopped working due to the load being too high.
The current welding process stops.
Action:
Check the equipment to make sure that everything is properly connected. It will
be necessary to turn off the power supply to reset the system. If the error persists, call a
service engineer.
15
Messages lost
The microprocessor cannot process incoming messages at the required speed, and
information has been lost.
Action
: It will be necessary to turn off the power supply to reset the system. If the error
persists, call a service engineer.
17
Lost contact
The controller has lost contact with the wire feeder.
The current welding process stops.
Action
: Check the cables. If the error persists, call a service engineer.
18
Lost contact
The controller has lost contact with the power unit.
The current welding process stops.
Action
: Check the cables. If the error persists, call a service engineer.
19
Memory error in battery--powered data memory RAM
The battery has no power.
Action:
Turn off the mains power supply to reset the system. Reset the controller. The
settings will be in English with MIG/MAG, DIP/SPRAY, Fe, CO2, 1.2 mm.
If the error persists, call a service engineer.
GB