-- 62 --
bi09d1e2
Error
code
Description
20
Non--permitted settings stored in RAM.
Non--permitted values have been found during start--up. Deletes all data in the controller.
Action:
Turn off the mains power supply to reset the system. Reset the controller. The
settings will be in English with MIG/MAG, DIP/SPRAY, Fe, CO2, 1.2 mm.
If the error persists, call a service engineer.
21
Incompatible settings stored in RAM.
Non--permitted weld data combinations have been entered.
Action
: It will be necessary to turn off the power supply to reset the system. If the error
persists, call a service engineer.
22
Transmitter buffer overflow
The controller cannot transmit information to the other units at a sufficiently high speed.
Action:
Turn off the mains power supply to reset the system.
23
Receiver buffer overflow
The controller cannot process information from the other units at a sufficiently high speed.
Action:
Turn off the mains power supply to reset the system.
25
Incompatible weld data format
Tried to store weld data on a PC card. The PC card has a different data format than the
weld data memory.
Action:
Use a different PC card.
26
Program error
Something has prevented the processor from performing its normal duties in the program.
The program is restarted automatically. The current welding process will be stopped. This
fault does not disable any functions.
Action:
Review the handling of welding programs during welding. If the error is repeated,
call a service engineer.
27
Out of wire (wire feeder)
The wire feeder is not feeding out any wire. The current welding process will be stopped,
and prevent welding from restarting.
Action:
Load new wire.
28
Program data lost
Program execution does not work.
Action:
Turn off the mains power supply to reset the system. If the error persists, call a
service engineer.
29
No cooling water flow
The flow monitor switch has been triggered.
The current welding process is stopped and cannot be restarted.
Action:
Check the cooling water circuit and the pump.
30
Lost contact with TIG card
The controller has lost contact with the TIG card. The current activity stops.
Action:
Check the cables. If the error persists, call a service engineer.
31
No reply from display unit
The microprocessor has no contact with the display card.
Action
: Call a service engineer.