ALARM TYPE
There are two kinds of alarm types: Normal Open and Normal Close,
which are illustrated as below. Select an alarm type that corresponds with
the alarm application.
ALARM ACTION
The alarm actions include PRESET, SEQUENCE, AUTOPAN and
CRUISE functions. Select one of these modes so that certain action will
be executed when an alarm is triggered. Use the right direction key of
the control keyboard to select a particular action mode, and the items
listed below will change in accordance with your selected alarm action.
Additionally, when an alarm is triggered, there will be a flash warning
notice: ALARM displayed in the upper right corner of the screen.
NOTE:
When alarm condition (dwell time setting: 1~127
seconds/ ALWAYS) is released, the Dome Camera will go back
to the previous status before alarm was triggered.
PRESET POINT
Select a preset point where the Dome Camera should go when an alarm
pin is triggered. The preset point(s) should be set prior either in the
PRESET setup menu or through the keyboard.
SEQUENCE LINE
Select a sequence line that the Dome Camera should execute when an
alarm pin is triggered. The sequence line(s) should be defined prior either
in the SEQUENCE setup menu or through the keyboard.
AUTOPAN LINE
Select an auto-pan line that the Dome Camera should execute when an
alarm pin is triggered. The auto-pan line(s) should be defined prior either
in the AUTOPAN setup menu or through the keyboard.
Normal
Open
Alarm
In
Normal
Close
Alarm
In