OSD Setup Manual
www.ernitec.com
42
Sequence Setup
The Sequence Setup menu allows users to set the camera sequence schedule and dwell
time for main and call monitor. Select <Sequence Setup> in main menu and press ENTER.
The menu displays as follows.
Sequence Setup
Main Monitor Dwell
Main Monitor Schedule
Call Monitor Dwell
Call Monitor Schedule
5 Sec
5 Sec
Items in the <Sequence Setup> menu are described in the following subsections.
<Main / Call Monitor Dwell>
The main / call monitor can be set to display full screen video of all installed cameras in
sequence. This item is used to set the Main Monitor dwell time, which is the duration of time
elapsed before switching to the next channel. The dwell time is in the range of 1 to 120
seconds. The default value is 5 seconds.
<Main / Call Monitor Schedule>
This item is used to set displaying sequence of connected cameras to be displayed on the
main / call monitor in full-screen format
.
Move the cursor to <Main Monitor Schedule> and
press ENTER. The menu is displayed as follows.
Main Monitor Schedule
_
►
_
►
_
►
_
►
_
►
_
►
_
►
_
►
_
►
_
►
_
►
_
►
_
►
_
►
_
►
_
Press Channel Keys To Select Channel
Press
◄
Key To Delete
Follow these steps to set a sequence:
•
Press LEFT direction key to delete the original setting.
•
Press the desired Channel keys to assign the camera to the position where
the cursor stops.
•
Continue the steps until the sequence is completed.
The maximum number of entries in a sequence equals to the number of channels. Users
can select fewer than the maximum entries for camera sequence and leave the remaining
entries blank. The sequence can include a specific camera or cameras multiple times.