background image

Keyboard 1500M/1501M Setup

If several parameters should be changed it is necessary to start from the beginning with each
parameter, by pressing the ESC and MENU keys at the same time, and entering the password.
The default password is 0000 (four times zero).

Default settings

The default settings are indicated with an '

*

' on the next page.

Each time a setting is changed, the keyboard is automatically re-booted in order to activate the
new setting. Invalid entries are not accepted, indicated by no key-beep.

Quick set-up

The basic settings of the keyboards 1500M/1501M can easily be set up, by pressing the
following keys during power ON of the keyboard:

ESC

 + 

0

:  Direct Camera Control - RS485 - 2400 baud

ESC

 + 

2

:  System Keyboard - RS232 - 19200 baud - Keyboard no. 2/3

ESC

 + 

3

:  System Keyboard - RS485 - 19200 baud - Keyboard no. 3

ESC

 + 

4

:  System Keyboard - RS485 - 19200 baud - Keyboard no. 4

ESC

 + 

5

:  System Keyboard - RS485 - 19200 baud - Keyboard no. 5

ESC

 + 

6

:  System Keyboard - RS485 - 19200 baud - Keyboard no. 6

The remaining settings are not affected by the above quick set-up procedure.

Change the keyboard type

Press the key 

1

 to change the keyboard type.

Press 

to set the keyboard for 

Direct Camera Contro

l, press 

to set the

keyboard for 

System Control

.

Change of keyboard address

Press the key 

to change the 

keyboard address

, press a number between 

3

and 

indicating the new 

keyboard address

.

Change the baud rate

Press the key 

to change the 

baud rate

 setting.

Press the key 

1

 for 1200 baud, 

2

 for 2400, 

3

 for 4800, 

for 9600, 

for 19200 or

for 38400 

baud rate

.

Change the interface type

Press the key 

to change the 

interface

 type.

Press 

to set RS-232 

interface

, press 

to set RS-485 

interface

.

Change the function of the AUX relays (refer to the AUX relays section on page 5)

Press the key 

to change the function of the 

AUX relays

.

Press 

for latched function, 

for un-latched, 

for 1801M mode.

Calibrate joystick (1501M only)

This is a service function. Use this function to re-calibrate the joystick in case e.g. pan & tilts are
moving although the joystick is released.

Press the key 

to activate the function

Release the joystick, including the focus!
Press the 

CLR 

key to calibrate the joystick.

Change the password

Installation and Setup instruction for Keyboard Series 1500

Page 6

Summary of Contents for 1500M

Page 1: ...OFFICE ERNITEC FRANCE PARC PEREIRE 95 RUE PEREIRE BAT D 78100 SAINT GERMAINE EN LAYE FRANCE TELEPHONE 1 39 21 12 00 TELEFAX 1 39 21 12 95 E MAIL ernitec fr magic fr GERMAN OFFICE ERNITEC GmbH STORMARNRING 28 22145 STAPELFELD GERMANY TELEPHONE 040 67 56 25 0 TELEFAX 040 67 56 25 25 E MAIL ernitec aol com JAPAN OFFICE ERNITEC JAPAN LTD 8 16 GAKUEN HIGASHIMACHI 1 CHOME KODAIRA SHI TOKYO 187 0043 JAPA...

Page 2: ...ed with keyboard 1501M or 1503M Keyboard types Keyboard 1500M is equipped with a serial port with selectable RS 232 RS 485 interface Keyboard 1501M is furthermore equipped with a joystick for variable speed operation of BDR 575 and the ICU Keyboard 1502M is equipped with a serial port with selectable RS 232 RS 485 interface and an ARC net port for connection to SYSTEM 500M and 1000M A LCD display ...

Page 3: ... 6 or 9 Negative signal 6 or 9 Negative signal All SYSTEM 1000M units are interconnected through the ARC net Also the keyboards might be connected to the ARC net Remember to terminate the ARC net line in both ends of the cable This is done by setting the belonging small switches to the 120 Ω or 100 Ω position corresponding to the characteristic impedance of the cable used refer to fig 1 12 Make su...

Page 4: ...n Desc Pin Desc 6 or 8 Pos X5 PCM IN X7 CTRL IN X12 PCM IN 2 N A 1 COM X3 ERNA 7 or 9 Neg X5 PCM IN X7 CTRL IN X12 PCM IN 1 N A 2 COM X3 ERNA 1 4 5 GND Do NOT connect Details on interconnecting various types of telemetry receivers and termination of the RS 485 line can be found on figure 3 Telemetry Receivers Series BDR 51X and BDR 55X and the BED 108 Control Signal Distributor Unit will terminate...

Page 5: ...oards having the same address When used as a matrix keyboard make sure the following parameters are set correct Keyboard type SysKbd System keyboard Communication media In accordance with the interface used Baud rate In accordance with baud rate set in SYSTEM 500M 1000M Keyboard address Make sure the address set is unique When used for direct control of telemetry receivers ICU s Keyboard type CamC...

Page 6: ...et up procedure Change the keyboard type Press the key 1 to change the keyboard type Press 1 to set the keyboard for Direct Camera Control press 2 to set the keyboard for System Control Change of keyboard address Press the key 2 to change the keyboard address press a number between 3 and 6 indicating the new keyboard address Change the baud rate Press the key 3 to change the baud rate setting Pres...

Page 7: ...Press the key 9 to change the password and enter the new password 4 digits Re enter the new password Installation and Setup instruction for Keyboard Series 1500 Page 7 ...

Page 8: ...word Re enter new password Setup is finished Direct Camera control 1 1 2 System keyboard Keyboard No 3 2 3 4 5 6 Keyboard No 4 Keyboard No 5 Keyboard No 6 4 9600 Baud 1200 Baud 3 1 2 3 2400 Baud 4800 Baud RS232 4 1 2 RS485 Aux latch 5 1 2 3 Beep HIGH Beep LOW 9 2 3 1 4 2 3 1 4 5 19200 Baud 2 Aux Nolatch Beep OFF 6 1 Default factory settings 6 38400 Baud 3 Aux 1801M Joystick calibrated 7 CLR ESC In...

Page 9: ...the valid baud rates Change of keyboard address Press the F9 key to get to the Kdb No menu Press the F4 key to toggle between the valid keyboard numbers Set the function of the AUX keys Press the F9 key to get to the AUX menu Press the F6 key to toggle between Latch No Latch 1801M function Change the password Press the F9 key to get to the Change Password menu Press F7 and enter the new password 4...

Page 10: ... Set Function of AUX relays in BDR 5XX ICU Change password Service menu only Enter Password XXXX F4 OpMode F6 Comm F7 Baud F9 XXXXXX XXXX XXXX More F4 Kbd No F6 AUX F7 Change F9 X XX XXXX Password More Enter Password XXXX Reenter Password XXXX F4 ArcNet F6 Error F7 S W F9 Stat Log Ver More F4 Beep F6 Reset F7 Test F9 XXXX Settings Joystick More Set beeper tone Reset keyboard settings to default ma...

Page 11: ...tions are now directed to camera 3 address 2 until a new camera is selected Select all cameras broadcast If all cameras should be operated simulteneously press Broadcast commands Warning When e g activating the pan functions all cameras will pan The broadcast function should therefore be used with care Zoom Change the focal length 1500M 1502M 1501M 1503M 1500M 1502M 1501M 1503M Zoom wide Zoom narr...

Page 12: ...500M 1502M 1501M 1503M Tilt up Tilt down JOYSTICK NOTE When controlling a variable speed Pan tilt BDR 575 or ICU pushing the joystick towards its extremes will increase speed Activating an AUX relay To activate AUX relay 2 press 2 ð ð AUX Activate AUX 2 relay Note If the Keyboard 1500 is set for No Latch operation the relay is automatically de activated when the AUX key is released If set for Latc...

Page 13: ...s press Start sequence The sequence of pre positions is automatically aborted when another function is operated Remove insert text Series BDR 550 only Remove insert the text generated by the currently controlled telemetry receiver 150XM Remove or Insert text from telemetry receiver Auto focus ICU only In order to switch to auto focus press AUTO ð ð or AUTO ð ð Enable auto focus Auto iris ICU only ...

Page 14: ...controlled ESC ð AUX Display preposition sequence stack Insert a preposition in the sequence stack To insert preposition number 1 in the sequence stack stored in the telemetry receiver 1 ð ð ESC ð ð VCR 1 1 ð ð SHIFT INS 1500M 1502M 1501M 1503M Insert preposition number 1 in the sequence stack Delete a preposition from the sequence stack To delete preposition number 1 from the sequence stack store...

Page 15: ... ð 6 ð ð Use pre position 8 as Homeposition with a 60 sec time out Note that the time out entry automatically is multiplied with 10 Max time out entry is 255 corresponding to 2550 seconds Set Auto panning limits available on the ICU BDR 575 only To set the two limit positions for auto panning for the camera being controlled 1 ð ð SHIFT AUTO 2 ð ð SHIFT AUTO 1501M 1503M only 1501M 1503M only Set au...

Reviews: