78
Continued from previous page
Edit control parameters?
Control parameter 1
Y
E
Press VIEW to get
program parameters
in screen-viewer
This question does
not appear if you are
using the normal
splicing process
Depending on the process
“Control parameter 1” is:
Max eccentricity,
Index limit,
Desired attenuation, or
Pull 1
Control parameter 2
E
Depending on the process
“Control parameter 2” is:
RTC current,
Threshold type,
Offset adjustment, or
Pull 2
Control parameter 3
E
Depending on the process
“Control parameter 3” is:
Acceptable offset,
Loss factor,
ECF factor, or
Pull 3
Edit splicing parameters?
N
Y
Press VIEW to get
program param-
eters in screen-
viewer
Prefuse time 0.2 s
N
Re-edit program?
Change security?
Y
Press VIEW to get
program parameters
in screen-viewer
Follow from same question in
the middle of the previous page
N
“Updating parameters...”
Splicing mode
Appendix C - Program editing flow chart
E
E
Prefuse current 10.0 mA
Gap 50.0
m
m
Overlap 10.0
m
m
Fusion time 1 0.3 s
Fusion current 1 10.5 mA
Fusion time 2 2.0 s
Fusion current 2 16.3 mA
Fusion time 3 2.0 s
Fusion current 3 12.5 mA
Left MFD 9.8
m
m
Right MFD 9.8
m
m
Set center position 255
AOA current 0.0 mA
Early prefusion No
Align accuracy 0.15
m
m
Loss shift 0 db
Auto Arc Center No
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E