25
STANDARD FIBER
NORMAL SPLICING
PREFUS TIME
0.2
PREFUSE CURR
10.0
GAP
50.0
OVERLAP
10.0
FUSION TIME 1
0.3
FUSION CURR 1
10.5
FUSION TIME 2
2.0
FUSION CURR 2
16 3
Imag
Prefusion
Cleaning
Current
M ATTENUATOR
AN SM + SM
xxxxx xx + xx
NORMAL SM +
ECCENTRIC SM + SM
ADVANCED OPERATION - Program structure overview
A
B
Program name ..........................................................
26
Certain limitations hold in splicing program names.
Fiber type ..................................................................
26
Various fiber types behave differently when spliced, so the fiber type
must be correctly specified in a splicing program.
C
Splicing process .......................................................
28
There are six different splicing processes available with the FSU 995
FA.
D
Program parameters ................................................
36
The parameters contain the quantitative information needed to execute
the various splicing programs. They are permanantly set in the case of
the pre-defined programs, however, can be edited in the case of
Programs 11-50.
The following elements form the backbone to all FSU 995 FA
splicing programs. Each will be described in greater detail on
the indicated pages.
ADVANCED OPERATION - Program structure overview