ERBAUER 254MM (10”) DOUBLE BEVEL SLIDING MITRE SAW
MAINTENANCE
Danger:
To avoid injury, never put
lubricants on the blade while it
is spinning.
WARNING!
To avoid ire or toxic
reaction, never use petrol, naphtha,
acetone, lacquer thinner or similar highly volatile
solvents to clean the mitre saw.
WARNING!
For your safety, this
saw is double-insulated. To avoid
electrical shock, ire or injury, use only parts
identical to those identiied in the parts list.
Reassemble exactly as the original assembly to
avoid electrical shock.
Replacing carbon brushes
Replace both carbon brushes when either has
less than 6 mm length of carbon remaining, or
if the spring or wire is damaged or burned. To
inspect or replace brushes, irst unplug the saw.
Then remove the black plastic cap (1) on the
side of the motor (2). Remove the cap cautiously,
because it is spring loaded. Then pull out the
brush and replace. Replace for the other side. To
reassemble reverse the procedure. The ears on
the metal end of the assembly go in the same
hole the carbon part its into. Tighten the cap
snugly, but do not overtighten. (See ig. 43)
Note:
To reinstall the same brushes, irst make
sure the brushes go back in the way they
came out. This will avoid serviceable brushes
undergoing a second ‘bedding in’ process that
could reduce motor performance and increases
wear.
Lower blade guard
Do not use the saw without the lower blade
guard. The lower blade guard is attached to the
saw for your protection. Should the lower guard
become damaged, do not use the saw until the
damaged guard has been replaced. Develop a
regular check to make sure the lower guard is
working properly. Clean the lower guard of any
dust or buildup with a damp cloth.
Fig 43
1
2