Appendix A-2
Rev. B
If the electric potential of CS1 is higher than that of CS2, the TM series printers are ready for
communication (the host is ready to receive data). If the electric potential of CS1 is lower than
that of CS2, the TM series printers are not ready for communication (the host is not ready to
receive data).
If the electric potential of DR1 is higher than that of DR2, the TM series printers are ready for
communication (the host is ready to receive data). If the electric potential of DR1 is lower than
that of DR2, the TM series printers are not ready for communication (the host is not ready to
receive data).
DR1
DR2 Function
H
L
Communication is available
L
H
Communication is not available