119
Printer Parts and Controls Summary
|
119
POST HEATER
OFF
Sets the temperature of the heater that dries the
printout. See the instructions that came with your
media to select the correct temperature for the
post heater.
30°C
to
50°C
(86 °F to 122 °F)
M/W ADJUSTMENT (MicroWeave adjustment)
LOW A to B
Minimizes the affect of the MicroWeave
adjustment. Select
LOW B
if white lines or uneven
print density is evident in prints using
LOW A
.
MEDIUM A to D
Prints areas between print head passes with a
wave form pattern. Select
MEDIUM B
,
C
, or
D
if
white lines or uneven print density is evident in
prints using
MEDIUM A
.
HIGH A to D
Prints like
MEDIUM M/W ADJUSTMENT
, but
slower to improve print quality. Select
HIGH B
,
C
,
or
D
if white lines or uneven print density is
evident in prints using HIGH A.
EXTRA HIGH A to B
Prints like
HIGH M/W ADJUSTMENT
, but only on
half of the print head nozzles (
EXTRA HIGH A
uses one half and
EXTRA HIGH B
uses the other
half). Select
EXTRA HIGH
to improve print quality
over
HIGH
printing.
PAPER SUCTION
HIGH
Adjusts the suction pressure used when feeding
the media. See the instructions that came with
your media to select the correct suction pressure
for it.
LOW
DRYING TIME
0.0sec
to
10.0sec
Selects a drying time for ink to avoid smearing.
Option and parameters
Description
Post Heater
Summary of Contents for Stylus Pro GS6000
Page 1: ...Epson Stylus Pro GS6000 SETUP AND USE GUIDE ...
Page 4: ......
Page 8: ...8 8 Contents ...
Page 68: ...68 68 Handling Media and Printouts ...
Page 88: ...88 88 Maintaining the Printer ...
Page 98: ...98 98 Cleaning Storing and Transporting the Printer ...
Page 124: ...124 124 Specifications ...