Epson Stylus Pro 7700/7710/7700M/7710M/7900/7910/9700/9710/9900/9910/WT7900/WT7910/9890/9908/7890/7908
Revision I
TROUBLE SHOOTING
Remedies for Service Call Error
134
Confidential
113E
CR
Velocity deviation
error
Detects that it is being driven at an irregularly faster speed than the
specified value.
Irregular load
Encoder failure
Motor driver failure
Motor failure
Replace the CR Encoder Sensor.
(See P.238)
Replace the Main Board Assy.
(See P.228)
Replace the CR Motor.
(See P.242)
113F
CR
Lock error
Detects that it is being driven at an irregularly slower speed than the
specified value.
Encoder cable is damaged.
Motor cable is damaged.
Irregular load
Encoder failure
Motor failure
Check if the Carriage Unit is correctly installed.
Check if there is some foreign material on the driving section of the
Carriage Unit.
Check the connection between the CR Encoder and the Main Board
Assy.
Check the connection between the CR Motor and the Main Board Assy.
Replace the CR Encoder Sensor.
(See P.238)
Replace the CR Motor.
(See P.242)
122A
PF
Overload error
The electric current flowing when driving the motor is irregularly large.
Encoder cable is damaged.
Motor cable is damaged.
Irregular load
Encoder failure
Motor failure
Check if there is some foreign material causing extra load between the
PF Motor and the PF roller.
Check the connection between the PF Encoder Sensor and the Main
Board Assy.
Check the connection between the PF Motor and the Main Board Assy.
Replace the PF Encoder Sensor.
(See P.263)
Replace the PF Motor.
(See P.264)
122B
PF
Over speed error
Detects that it is being driven at an irregularly faster speed than the
specified value just before stopping.
Irregular load
Encoder failure
Replace the PF Encoder Sensor.
(See P.263)
122C
PF
Reversing error
Detects that it is being driven in the opposite direction to the specified
driving direction.
The polarity of encoder cable is opposite.
The polarity of motor cable is opposite.
Encoder failure
Irregular load
Check the connection between the PF Encoder Sensor and the Main
Board Assy.
Check if there is some foreign material causing extra load between the
PF Motor and the PF roller.
Replace the PF Encoder Sensor.
(See P.263)
122D
PF
Driving time-out
error
Detects that the driving period is irregularly long.
Irregular load
Firmware becomes out of control.
Replace the Main Board Assy.
(See P.228)
Error Code
Error Details
Description
Remedy
Failed Part
Error Name
Summary of Contents for Stylus Pro 7890 Series
Page 15: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 94: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 105: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 166: ...Confidential C H A P T E R 4 DISASSEMBLY ASSEMBLY ...
Page 351: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 444: ...Confidential C H A P T E R 6 MAINTENANCE ...
Page 459: ...Confidential C H A P T E R 7 EpsonStylusPro7700M 7710M CopyMode ...