5. The Adjustment Program automatically judges from the entered value whether the adjustment in the PF
direction is necessary.
When the adjustment in the PF direction is necessary (the value is ± 3 or over):
The program indicates which way to move the head angular adjustment lever, so follow the instruction and set the
lever to the correct position, then move on to
When the adjustment in the PF direction is not necessary:
Finish the adjustment.
Figure 2-23. Adjustment in the PF Direction
6. Print the adjustment pattern again and enter the values of the band pattern and microweave pattern, and then
click the Input button.
The adjustment is complete if the adjustment instruction in the PF direction no longer appears.
When the adjustment instruction in the PF direction appears, reinstall the Printhead and perform the
adjustment from the beginning.
Make sure to use tweezers when adjusting the head angular adjustment lever.
CR Unit
Head angular
adjustment lever
#1
#6
#6
#1
Front side of CR
Unit moves down.
Front side of CR
Unit moves up.
Adjust the head angular adjustment lever position by
following the instruction in Adjustment Program.