Revision A
Figure 2-29. Illustration of Calibration Chart
6. After the Calibration Chart is printed, allow it to dry for five minutes. During this time, check the nozzle
check pattern on the chart. If there are broken lines or missing segments, click [Print Calibration Chart
again], and return to
. If there are no broken lines or missing segments, click [Next].
Figure 2-30. Drying the Chart
The recommended air temperature range for printing a Calibration Chart is 15°C to 28°C.
2010-11-26 17:21(GMT 2010-11-26 08:21)
S/N: OS:Win BlackInk:Matte
Printer:EPSON PX-5V
2010-12-03 17:16(GMT 2010-12-03 08:16)
Print time
USB ID (18 alphanumeric digits) + OS + Black ink type
Color measurement limit time (7 days after the print time)
Product name (EPSON Stylus Photo R3000)
128 calibration patches
Nozzle check pattern
When there are broken
lines or missing segments