Adjustment
Details of Adjustments (TBD)
58
Epson Stylus Photo R3000
Revision A
2.2.8.2 Adjusting Method of the Colorimetric Calibration
The following illustrates the overall workflow.
Figure 2-26. Overall Workflow
1. Connect the printer and the calibrator with the PC to which the Colorimetric Calibration Tool for the printer
is installed using USB cables. Then turn the printer on.
2. Start up the Colorimetric Calibration Tool.
3. Load one sheet of A4 or letter-size plain paper, and click “Next” to print a nozzle check pattern.
The Color ID Calibration Chart is designed to be printed in a completely non-compensated
state. Therefore, there is no need to delete an existing Color ID from EEPROM when printing
out a Calibration Chart.
Install the printer driver for Epson Stylus Photo R3000 and USB driver for the
calibrator to the PC in advance.
To prevent inks from settling down at the bottom, remove the ink cartridges, and shake
them four or five times, then reinstall them to the printer before starting.
START
Printing of a nozzle
check pattern
Printing of a Calibration Chart
*USB ID / printing date/time / nozzle check pattern
Drying of the Calibration Chart (five minutes)
Confirmation of USB ID / printing date/time
Measure the Calibration Chart.
Convert the color values (Lab) to Color ID
from color measurement data.
Write the Color ID to a printer.
End
OK
NG
Head cleaning
Remove each ink cartridge, and
shake it four or five times, then
reinstall it.
The Colorimetric Calibration Tool
performs this process automatically.
Connect the printer and
calibrator to the PC,
and start the Colorimetric
Calibration Tool.