FX-2180 Service Manual
Disassembly and Assembly
Rev. A
4-16
4.2.9.3 Removing the PG Sensor Assembly
1.
Remove the printer cover, the rear / front edge guide assemblies, front
cover, paper eject assembly, and rear / fronts tractor units. (Refer to
Section 4.2.1.)
2.
Remove the panel board assembly. (Refer to Section 4.2.2.)
3.
Remove the upper housing assembly. (Refer to Section 4.2.7.)
4.
Remove the printer mechanism. (Refer to Section 4.2.9.)
5.
Remove one hexagon nut (M4) securing the PG sensor assembly to the
right frame assembly.
H e x a g o n N u t
P G S e n s o r A s s e m b l y
Figure 4-18. Removing the PG Sensor Assembly
CHECK POINT
9
When the sensors are mounted to the PG sensor
holder be sure to mount the while connector’s
sensor in the upper position as shown in the
following figure.
When securing the shaft, push the front CR
guide shaft to the bottom of the cutout.
The tightening torque for the hexagon nut : 1.18
∼∼
1.37 Nm (12
∼∼
14 Kgf-cm)
P G S W 1
( W h i t e c o n n e c t o r )
P G S W 2
( B l a c k c o n n e c t o r )
Figure 4-19. Mounting the Sensors for PG Sensor Holder
Summary of Contents for FX-2180 - Impact Printer
Page 1: ...EPSON EPSON EPSON France S A SERVICE MANUAL FX 2180 PRODUIT ...
Page 2: ...6 59 0 18 3LQ PSDFW RW 3ULQWHU EPSON FX 2180 4009047 ...
Page 6: ...REVISION STATUS Rev Date Page s Contents A 1998 04 02 All First release ...
Page 11: ...PRODUCT DESCRIPTIONS 3 7 5 ...
Page 24: ...OPERATING PRINCIPLES 3 7 5 ...
Page 28: ...TROUBLESHOOTING 3 7 5 ...
Page 43: ...DISASSEMBLY AND ASSEMBLY 3 7 5 ...
Page 76: ...ADJUSTMENT 3 7 5 ...
Page 86: ...MAINTENANCE 3 7 5 ...
Page 89: ...APPENDIX 3 7 5 ...
Page 101: ......
Page 104: ......