6-50
Assembly and Disassembly
Rev. A
Confidential
4
Insulating tape (consumable)
❏
Fold the
cable, printer
and fix it with a 70 mm long
insulating tape
.
5
Plate, opening and shutting
assembly
×
1
C.B.S-tite (M3
××××
5)
×
2
❏
Secure the
plate, opening and shutting assembly
to the
fixing plate,
printer assembly
with
C.B.S-tite (M3
××××
5)
screws.
★
< Check >
❏
Tightening torque: 735 to 931 mN
•
m {7.5 to 9.5 kg
•
cm}
❏
Do not attach the
plate, opening and shutting assembly
when an
optional 600 mm
loop guide
is equipped.
Reassembly
step
Part name
Assembly procedure
cable, printer
insulating tape
C.B.S-tite (M3
×
5)
plate, opening and
shutting assembly