Feed Jam (Paper Out)
Description
No paper has been fed even though printer has started printing action.
The error is cleared when there is no longer any paper jam detected after
opening and closing the front cover.
After error recovery, data for one page retained in the printer memory are
recovered if it is possible, and if the data cannot be recovered, the printer
returns a resending request. The data is recovered when the printer does not
perform a flying start. Cleaning is not executed after the error recovery.
Remedy
If there is no paper, set paper and open and close the front cover. In the case of
a jam, remove the jammed paper which was not fed and open and close the
front cover. Then printing resumes from the jammed page. The pop-up
display of the EPSON Status Monitor disappears after error recovery.
The error can be cleared through the Status Monitor even without opening and
closing the cover.
Install Imaging Cart
Description
The Imaging Cartridge is not set or not set correctly. The error is cleared when
the Imaging Cartridge is detected.
(When no CSIC is found, the error occurs.)
Remedy
Open the cover, set the Imaging Cartridge properly and close the cover again
to clear the error. The pop-up display of the EPSON Status Monitor
disappears after error recovery.
5)Imaging cartridge ID error
Description
The Developer Cartridge is not for this printer or the cartridge is broken.
This error will occur when the printer judges the Developer Cartridge is not
the appropriate EPSON worldwide model with a capacity of 3k or 1.5K.
Remedy
Open the cover, set the correct Developer Cartridge and close the cover again
to clear the error. The pop-up display of the EPSON Status Monitor
disappears after error recovery.
NonGenuineToner Cart
Description
The installed Developer Cartridge (toner cartridge) is judged to be not
EPSON genuine.
CAUSE 1. The manufacture ID is not the ID of EPSON.
2. The toner counter has been returned.
Remedy
Open the cover, set the correct Developer Cartridge (toner cartridge) and
close the cover again to clear the error. The pop-up display of the EPSON
Status Monitor disappears after error recovery.
If user want to use the non genuine cartridge, select [Continue] on the EPSON
Status Monitor.
After select [Continue], NonGenuineTonerCart warning occurs.
Image Cart R/W Error
Description
Normal access to the CSIC of the Developer Cartridge is impossible.
This error will be cleared when it is detected that a Developer Cartridge with a
normal CSIC has been set.
Remedy
Open the cover, set the correct Developer Cartridge and close the cover again
to clear the error. The pop-up display of the EPSON Status Monitor
disappears after error recovery.
Toner Out
Description
The toner life counter has reached the end of its service life (0%).
When the consumables expire while printing is underway, the operation stops
before the next page is printed. This error occurs only when Toner Out Error =
STOP.
Remedy
Replacing the Developer Cartridge (toner cartridge) with a new one clears the
error, and the pop-up message of the EPSON Status Monitor disappears.
NOTE:
If you change the Toner Out Error = Continue, then the status
becomes Toner Low and you can print again.
Summary of Contents for EPL-6200
Page 1: ...EPSON EPL 6200 EPL 6200L A4 Monochrome Page Printer SERVICE MANUAL ROSCO SEPG03002 ...
Page 7: ...Revision Status Revision Date of Issue Description A September 5 2003 First release ...
Page 12: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 67: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 99: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 129: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 165: ...C H A P T E R 5 ADJUSTMENT ...
Page 172: ...C H A P T E R 6 MAINTENANCE ...
Page 175: ...C H A P T E R 7 APPENDIX ...
Page 180: ......
Page 181: ......
Page 182: ......
Page 183: ......
Page 184: ......
Page 185: ......