EPSON EPL-6200/EPL-6200L
Revision A
Troubleshooting
Troubleshooting When There is Error Display
108
3.2.2 Fan problem
The following condition is handled as a fan problem:
During operation of the Cooling Fan Motor, the lock signal (H or L) has been
maintained for more than the predetermined period of time.
3.2.3 Polygon Motor Error
Any of the following conditions is handled as an polygon motor error:
The lock signal was not detected within the predetermined period of time
counted from one second after start of the polygon motor.
The lock signal was not detected during the period of 1 second counted from
1.5 seconds after emission of the first lock signal.
No lock signal was detected for 0.5 second continuously under the conditions
where the polygon motor was in a steady running state.
The lock signal was kept ON for more than 5 seconds even with the polygon
motor turned OFF.
Table 3-5. Troubleshooting for “Fan problem”
Step
Action and Question
Yes
No
Parts below can be the source of this error (
Chapter 4 Disassembly and Assembly
)
•
Cooling Fan Motor
(p.155)
•
Main Board Assy (C533/C534 Main)
(p.146)
•
Power Supply Unit (PU1)
(p.151)
1
Cooling Fan Motor 1
Check the connection of the motor connector, and
correct it if any problem is found.
♦
Has the error been cleared?
Problem
solved
Go to Step 2
2
Cooling Fan Motor 2
Check the loading on the fan mechanism, and correct
it if any problem is found.
♦
Has the error been cleared?
Problem
solved
Go to Step 3
3
Cooling Fan Motor 3
Replace the cooling fan.
♦
Has the error been cleared?
Replace the
cooling fan.
Go to Step 4
4
Main Board Assy.
Replace the Main Board Assy.
♦
Has the error been cleared?
Replace the
Main Board
Assy.
Go to
“3.4.2
Electrical
Noise”
(p.120)
Table 3-6. Troubleshooting forTroubleshooting for “Polygon Motor Error”
Step
Action and Question
Yes
No
Parts below can be the source of this error (
Chapter 4 Disassembly and Assembly
)
•
PH Unit
(p.154)
• FFC
•
Main Board Assy (C533/C534 Main)
(p.146)
1
Connection with connectors
Check the connection of the cable, and correct it if
any problem is found.
♦
Has the error been cleared?
Problem
solved
Go to Step 2
2
PH unit
Replace the PH unit.
♦
Has the error been cleared?
Replace the
PH unit.
Go to Step 3
3
Main Board Assy.
Replace the Main Board Assy.
♦
Has the error been cleared?
Replace the
Main Board
Assy.
Go to
“3.4.2
Electrical
Noise”
(p.120)
Summary of Contents for EPL-6200
Page 1: ...EPSON EPL 6200 EPL 6200L A4 Monochrome Page Printer SERVICE MANUAL ROSCO SEPG03002 ...
Page 7: ...Revision Status Revision Date of Issue Description A September 5 2003 First release ...
Page 12: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 67: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 99: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 129: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 165: ...C H A P T E R 5 ADJUSTMENT ...
Page 172: ...C H A P T E R 6 MAINTENANCE ...
Page 175: ...C H A P T E R 7 APPENDIX ...
Page 180: ......
Page 181: ......
Page 182: ......
Page 183: ......
Page 184: ......
Page 185: ......